Basra Manchester
SHADINAL-JANOOB Send an enquiry

Home / Cathodic protection

Cathodic protection for pipelines, wells and tanks.

Buried and submerged steel in southern Iraq faces saline, high-chloride soils. We supply and install complete cathodic protection systems built by UK and European manufacturers, and commission them to the operator's protection criteria.

Impressed-current CP: AC supply to a transformer-rectifier; negative to the pipeline through a junction box, positive to a deep-well MMO anode groundbed; test station measuring pipe-to-soil potential against a copper sulphate reference electrode. AC SUPPLY · 415 V 3φ T/R50 V · 50 A (+)(−) J/BOX GRADE MMO ANODESDEEP-WELL GROUNDBEDCOKE BACKFILL BURIED PIPELINE · FBE COATED TS-04 Cu/CuSO₄ REF. PROTECTION CRITERIONE(off) ≤ −850 mV vs CSE TITLEICCP ARRANGEMENT · TYPICALDWG NO.SHJ-C-001SCALENTS

Supply

Equipment for complete CP systems

We quote complete packages so a buyer deals with one supplier, from the rectifier to the last test post. Every item ships with manufacturer certificates and test records.

C1

Transformer-rectifiers

  • Air- and oil-cooled units
  • Safe-area and hazardous-area versions
  • Constant current or constant voltage control
  • Optional remote monitoring
C2

Anodes and groundbeds

  • MMO tubular and ribbon anodes
  • Magnesium and zinc galvanic anodes
  • Deep-well and shallow groundbeds
  • Calcined petroleum coke backfill
C3

Junction boxes and test stations

  • Anode and cathode junction boxes with shunts
  • Above-ground test posts
  • Permanent reference electrodes
  • Coupons for instant-off readings
C4

Cables and connections

  • Anode tail and header cables
  • Thermite and pin-brazed connections
  • Splice kits and cable markers
C5

Isolation and bonding

  • Insulating joints and flange kits
  • Surge arrestors and polarisation cells
  • Resistance bonds for crossings
C6

Survey instruments

  • Portable reference electrodes
  • Current interrupters and data loggers
  • Soil resistivity meters

Services

From survey to commissioning

Design is carried out with qualified CP engineers from our UK manufacturing partners. Our Basra crews install, test and hand over.

  1. Survey

    Soil resistivity, existing potentials and current requirement tests.

  2. Design

    Groundbed and rectifier sizing to the operator's specification.

  3. Supply

    UK and European equipment, documented and delivered to site.

  4. Install

    Groundbed drilling, cable laying, connections and test stations.

  5. Commission

    On and instant-off potential surveys and a full commissioning report.

Standards

Built and tested to recognised standards

We work to the standard the operator names. Typical references for Iraqi pipeline and facility work are listed here. The usual protection criterion for buried steel is an instant-off potential of −850 mV or more negative against a copper/copper sulphate reference electrode.

Pipelines
ISO 15589-1 · AMPP SP0169
General
BS EN 12954
Rectifiers
IEC 61439 assemblies · ATEX / IECEx for hazardous areas
Criterion
E(off) ≤ −850 mV vs Cu/CuSO₄
Documents
Factory test records, certificates of conformity, Iraqi CoC per shipment

Planning a power, control or CP package in southern Iraq?

Send us the scope or tender documents. We reply with a priced proposal or our pre-qualification pack.